Pre-stressed structural systems

Precast inverted T-beam floor and roof systems

Carry more. Build with less.

Custom-length inverted T-beams engineered for efficient load distribution, dependable structural performance, and streamlined site assembly.

Pre-stressed inverted T-beams
TStructural system

Engineered support

A more efficient path across the span.

The inverted T profile creates a structural ledge that supports infill elements while the pre-stressed beam carries the assembly.

Manufactured in custom lengths, the system can reduce site formwork and wet trades while supporting dependable floors and roofs across larger projects.

  • Pre-stressed concrete with high-tensile reinforcement
  • Consistent manufactured cross-section
  • Adaptable to varied span requirements
  • Designed for demanding environments

The advantage

Less complexity on site. More certainty in the structure.

The system shifts important work into a controlled manufacturing process and simplifies assembly at the project.

01

Reduced formwork

Precast components can limit conventional forming, reinforcing, and wet concrete work on site.

02

Faster assembly

A repeatable beam-and-infill system supports more efficient floor and roof construction.

03

Structural capacity

Pre-stressing and the T-section geometry support substantial project demands.

04

Integrated insulation

EPS infill components can improve thermal performance compared with solid concrete assemblies.

Inverted T-beam structural assembly

System features

Manufactured for repeatable performance.

01

High-tensile pre-stressing reinforcement

02

Custom lengths for project requirements

03

High load-bearing potential

04

Floor and roof system versatility

Where it works

Built for projects that need dependable support.

Final spans, loading, reinforcement, and assembly requirements must be determined for the specific project.

Discuss technical requirements

Span guide

Maximum clear spans for Stelcor prestressed inverted T-beams at 24-inch centres with a 3-inch normal-weight concrete topping and mesh. Load tables include a 25 lb/ft² superimposed dead-load allowance.

BeamResidential floorOffice floor
5-inch inverted T-beamup to 16.5 ftup to 15.5 ft
8-inch inverted T-beamup to 22 ftup to 20 ft

Every project is checked by an engineer for its actual loads and layout.

Specifications

  • Prestressing strand: 210 ksi
  • Concrete strength: f'c 5,000 psi
  • Strand: 4 lower and 1 upper 5 mm cables
  • Beam spacing: 24 inches on centre
  • Topping: 3 inches of normal-weight concrete with mesh 66-88

Frequently asked questions

What is an inverted T-beam floor?

It is a floor or roof built from precast, prestressed concrete beams shaped like an upside-down T, placed side by side with infill between them and finished with a concrete topping. It replaces most of the formwork and shoring a fully cast-in-place slab needs.

How far can the beams span?

Up to 16.5 ft for a 5-inch beam and up to 22 ft for an 8-inch beam on residential floors, with shorter spans for office loads. See the span guide above.

Can the beams cantilever or run continuously over a support?

No. The beams are always simply supported, bearing at each end. They are never cantilevered and never continuous over a support. Balconies and overhangs need to be designed separately.

Can I use T-beams for a concrete roof?

Yes. The system is used for second-storey floors, suspended slabs and concrete roofs, subject to engineering for the roof loads and waterproofing.

Do I still need an engineer?

Yes. Send your drawings and loads and the layout is checked for your project.

Engineer the span

Bring us the loading, layout, and project goals.

We’ll help coordinate the next conversation around the structural system.

Start a T-beam inquiry →